HR2000 and HR2000CG-UV-NIR Series
High-Resolution Fiber Optic
Spectrometers
HR2000 / HR2000CG-UV-NIR
Installation and Operation Manual
Document Number 194-00000-000-02-0208
Offices:
Ocean Optics, Inc.
830 Douglas Ave., Dunedin, FL, USA 34698
Phone 727.733.2447
Fax 727.733.3962
8:30 a.m.-6 p.m. EST
Ocean Optics B.V. (Europe)
Nieuwgraaf 108 G, 6921 RK DUIVEN, The Netherlands
Phone 31-(0)26-3190500
F
ax 31-(0)26-3190505
E-mail: [email protected] (General sales inquiries)
[email protected] (European sales inquiries)
[email protected]om (Questions about orders)
TechSupport@OceanOptics.com (Technical support)
Page view 0
1 2 3 4 5 6 ... 41 42

Summary of Contents

Page 1 - HR2000 / HR2000CG-UV-NIR

HR2000 and HR2000CG-UV-NIR Series High-Resolution Fiber Optic Spectrometers HR2000 / HR2000CG-UV-NIR Installation and Operation Manual Docume

Page 2

HR2000 Specifications HR2000 High-Resolution Fiber Optic Spectrometer 6 HR2000 Specifications Table Ocean Optics permanently secures all components

Page 3 - Table of Contents

HR2000 Specifications HR2000 High-Resolution Fiber Optic Spectrometer 7 HR2000 Specifications The following sections provide specification informat

Page 4

HR2000 Specifications HR2000 High-Resolution Fiber Optic Spectrometer 8 System Compatibility The following sections provide information on hardware

Page 5 - 1 HR2000 Introduction

HR2000 Specifications HR2000 High-Resolution Fiber Optic Spectrometer 9 20-Pin Accessory Connector Pinout Diagram When facing the 20-pin Accessory

Page 6 - Modular Sampling Accessories

Installing the HR2000 HR2000 High-Resolution Fiber Optic Spectrometer 10 3 Installing the HR2000 This chapter contains instructions in parallel fo

Page 7 - Shipment Components

Installing the HR2000 HR2000 High-Resolution Fiber Optic Spectrometer 11 Configuring the HR2000 in OOIBase32 Once you install the HR2000, you must

Page 8 - Other Documentation

Installing the HR2000 HR2000 High-Resolution Fiber Optic Spectrometer 12 Configure Hardware Screen - Continued USB Mode 1. Specify S2000/PC2000/U

Page 9 - 2 HR2000 Specifications

Installing the HR2000 Spectrometer Configuration Screen The Spectrometer Configuration screen prompts you to configure specific channel-level spectr

Page 10 - HR2000 Specifications Table

Troubleshooting HR2000 High-Resolution Fiber Optic Spectrometer 14 4 Troubleshooting The following sections contain information on troubleshooting

Page 11 - HR2000 Specifications

Troubleshooting HR2000 High-Resolution Fiber Optic Spectrometer 15 4. Click the OK button to continue. A warning box appears confirming the removal

Page 12 - System Compatibility

Copyright © 2001-2008 Ocean Optics, Inc. All rights reserved. No part of this publication may be reproduced, stored

Page 13

Troubleshooting HR2000 High-Resolution Fiber Optic Spectrometer 16 Windows 2000/XP: Remove Improperly Installed Files: 1. Open Windows Explorer. 2.

Page 14 - 3 Installing the HR2000

Troubleshooting HR2000 High-Resolution Fiber Optic Spectrometer 17 Troubleshooting the Serial Port Configuration Occasionally, you may encounter pr

Page 15 - Installing the HR2000

Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 18 5 Sample Experiments The following sections contain information on conducting

Page 16

Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 19 Application Tips If the signal you collect is saturating the spectrometer (in

Page 17 - External Triggering Options

Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 20 Absorbance Experiments Absorbance spectra are a measure of how much light a

Page 18 - 4 Troubleshooting

Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 21 3. Place a sample of the solvent into a cuvette and take a reference spectru

Page 19 - Windows 98:

Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 22 Transmission Experiments Transmission is the percentage of energy passing th

Page 20 - Windows 2000/XP:

Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 23 6. Place a sample of the solvent into a cuvette and take a reference spectru

Page 21 - Troubleshooting

Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 24 Reflection Experiments Reflection is the return of radiation by a surface, w

Page 22 - 5 Sample Experiments

Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 25 Perform the following steps to take reflection measurements using OOIBase32:

Page 23 - Sample Experiments

Table of Contents Chapter 1: HR2000 Introduction ...

Page 24 - Absorbance Experiments

Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 26 Relative Irradiance Experiments Irradiance is the amount of energy at each w

Page 25

Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 27 Perform the following steps to take a relative irradiance measurement using O

Page 26 - Transmission Experiments

Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 28 Time Acquisition Experiments OOIBase32 allows you to perform time acquisitio

Page 27

Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 29 3. Configure a time acquisition process for a combination of two time channe

Page 28 - Reflection Experiments

Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 30 6. Enable Save Every Acquisition to store data for every spectral acquisition

Page 29

Appendix A HR2000 High-Resolution Fiber Optic Spectrometer 31 Appendix A: Calibrating the Wavelength of the HR2000 This Appendix describes how to

Page 30

Appendix A Calibrating the Wavelength of the Spectrometer Perform the steps below to calibrate the wavelength of the spectrometer: 1. Place OOIBase

Page 31

Appendix A 5. Use the spreadsheet or calculator to calculate the wavelength calibration coefficients. In the spreadsheet program, find the functio

Page 32

Appendix A Saving the New Calibration Coefficients: USB Mode Ocean Optics programs wavelength calibration coefficients unique to each HR2000 onto an

Page 33

Appendix A Saving the New Calibration Coefficients: Serial Mode If you are connecting the HR2000 Spectrometer to the serial port of the PC, you need

Page 34

Chapter 5: Sample Experiments...18 Preparing

Page 35 - Preparing for Calibration

Appendix B Appendix B: HR2000CG-UV-NIR Spectrometer The HR2000CG-UV-NIR Composite Grating Spectrometer has a new proprietary grating and order-sort

Page 36 - Appendix A

Index A Accessories, 2, 13 Accessory Connector, 8 Diagram, 9 Pin Definitions, 9 Pinout, 8 Adobe Acrobat Reader, 4 C Calibrating, 31 CCD, 7 CCD Detect

Page 37

W Wavelength Calibration, 31 Wavelength Calibration Data File, 3 Wavelength Calibration Data Sheet, 3 HR2000 High-Resolution Fiber Optic Spectrom

Page 38

HR2000 Introduction HR2000 High-Resolution Fiber Optic Spectrometer 1 1 HR2000 Introduction The following chapter contains introductory information

Page 39

HR2000 Introduction HR2000 High-Resolution Fiber Optic Spectrometer 2 EEPROM Utilization An EEPROM memory chip in each HR2000 contains wavelength c

Page 40 - HR2000CG-UV-NIR Features

HR2000 Introduction HR2000 High-Resolution Fiber Optic Spectrometer 3 Interface Options The HR2000 has both USB and serial port connectors (with th

Page 41

HR2000 Introduction HR2000 High-Resolution Fiber Optic Spectrometer 4 Software and Technical Resources CD Each order ships with the Ocean Optics So

Page 42 - Wavelength Calibration, 31

HR2000 Specifications HR2000 High-Resolution Fiber Optic Spectrometer 5 2 HR2000 Specifications This chapter contains information on spectrometer o