HR2000 and HR2000CG-UV-NIR Series High-Resolution Fiber Optic Spectrometers HR2000 / HR2000CG-UV-NIR Installation and Operation Manual Docume
HR2000 Specifications HR2000 High-Resolution Fiber Optic Spectrometer 6 HR2000 Specifications Table Ocean Optics permanently secures all components
HR2000 Specifications HR2000 High-Resolution Fiber Optic Spectrometer 7 HR2000 Specifications The following sections provide specification informat
HR2000 Specifications HR2000 High-Resolution Fiber Optic Spectrometer 8 System Compatibility The following sections provide information on hardware
HR2000 Specifications HR2000 High-Resolution Fiber Optic Spectrometer 9 20-Pin Accessory Connector Pinout Diagram When facing the 20-pin Accessory
Installing the HR2000 HR2000 High-Resolution Fiber Optic Spectrometer 10 3 Installing the HR2000 This chapter contains instructions in parallel fo
Installing the HR2000 HR2000 High-Resolution Fiber Optic Spectrometer 11 Configuring the HR2000 in OOIBase32 Once you install the HR2000, you must
Installing the HR2000 HR2000 High-Resolution Fiber Optic Spectrometer 12 Configure Hardware Screen - Continued USB Mode 1. Specify S2000/PC2000/U
Installing the HR2000 Spectrometer Configuration Screen The Spectrometer Configuration screen prompts you to configure specific channel-level spectr
Troubleshooting HR2000 High-Resolution Fiber Optic Spectrometer 14 4 Troubleshooting The following sections contain information on troubleshooting
Troubleshooting HR2000 High-Resolution Fiber Optic Spectrometer 15 4. Click the OK button to continue. A warning box appears confirming the removal
Copyright © 2001-2008 Ocean Optics, Inc. All rights reserved. No part of this publication may be reproduced, stored
Troubleshooting HR2000 High-Resolution Fiber Optic Spectrometer 16 Windows 2000/XP: Remove Improperly Installed Files: 1. Open Windows Explorer. 2.
Troubleshooting HR2000 High-Resolution Fiber Optic Spectrometer 17 Troubleshooting the Serial Port Configuration Occasionally, you may encounter pr
Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 18 5 Sample Experiments The following sections contain information on conducting
Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 19 Application Tips If the signal you collect is saturating the spectrometer (in
Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 20 Absorbance Experiments Absorbance spectra are a measure of how much light a
Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 21 3. Place a sample of the solvent into a cuvette and take a reference spectru
Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 22 Transmission Experiments Transmission is the percentage of energy passing th
Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 23 6. Place a sample of the solvent into a cuvette and take a reference spectru
Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 24 Reflection Experiments Reflection is the return of radiation by a surface, w
Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 25 Perform the following steps to take reflection measurements using OOIBase32:
Table of Contents Chapter 1: HR2000 Introduction ...
Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 26 Relative Irradiance Experiments Irradiance is the amount of energy at each w
Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 27 Perform the following steps to take a relative irradiance measurement using O
Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 28 Time Acquisition Experiments OOIBase32 allows you to perform time acquisitio
Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 29 3. Configure a time acquisition process for a combination of two time channe
Sample Experiments HR2000 High-Resolution Fiber Optic Spectrometer 30 6. Enable Save Every Acquisition to store data for every spectral acquisition
Appendix A HR2000 High-Resolution Fiber Optic Spectrometer 31 Appendix A: Calibrating the Wavelength of the HR2000 This Appendix describes how to
Appendix A Calibrating the Wavelength of the Spectrometer Perform the steps below to calibrate the wavelength of the spectrometer: 1. Place OOIBase
Appendix A 5. Use the spreadsheet or calculator to calculate the wavelength calibration coefficients. In the spreadsheet program, find the functio
Appendix A Saving the New Calibration Coefficients: USB Mode Ocean Optics programs wavelength calibration coefficients unique to each HR2000 onto an
Appendix A Saving the New Calibration Coefficients: Serial Mode If you are connecting the HR2000 Spectrometer to the serial port of the PC, you need
Chapter 5: Sample Experiments...18 Preparing
Appendix B Appendix B: HR2000CG-UV-NIR Spectrometer The HR2000CG-UV-NIR Composite Grating Spectrometer has a new proprietary grating and order-sort
Index A Accessories, 2, 13 Accessory Connector, 8 Diagram, 9 Pin Definitions, 9 Pinout, 8 Adobe Acrobat Reader, 4 C Calibrating, 31 CCD, 7 CCD Detect
W Wavelength Calibration, 31 Wavelength Calibration Data File, 3 Wavelength Calibration Data Sheet, 3 HR2000 High-Resolution Fiber Optic Spectrom
HR2000 Introduction HR2000 High-Resolution Fiber Optic Spectrometer 1 1 HR2000 Introduction The following chapter contains introductory information
HR2000 Introduction HR2000 High-Resolution Fiber Optic Spectrometer 2 EEPROM Utilization An EEPROM memory chip in each HR2000 contains wavelength c
HR2000 Introduction HR2000 High-Resolution Fiber Optic Spectrometer 3 Interface Options The HR2000 has both USB and serial port connectors (with th
HR2000 Introduction HR2000 High-Resolution Fiber Optic Spectrometer 4 Software and Technical Resources CD Each order ships with the Ocean Optics So
HR2000 Specifications HR2000 High-Resolution Fiber Optic Spectrometer 5 2 HR2000 Specifications This chapter contains information on spectrometer o